Every 6513 have 2x WS-CAC-3000W power supply working in active redundancy mode. The system comprises a chassis, power supplies, one or two supervisors, line cards and service modules. Currently we have 3 sites. In order to change the native VLAN on the interface that is trunking, issue the switchport trunk native vlan vlan_number command. The Cisco Catalyst 6500 Series Gigabit Ethernet modules support multiple queues per port for Quality of Service. The Future Is 40 Gigabit Ethernet White Paper (PDF - 2 MB) Virtual Private LAN Service on Cisco Catalyst 6500 Supervisor Engine 2T. Do the Express Setup to enter the initial IP information. SSH was introduced into these Cisco IOS. 2 (18r)SX9, RELEASE SOFTWARE (fc1) Cat6k-Sup32 platform with 524288 Kbytes of. 2 No. As soon as I type this command at Global configuration dhcp server start assigning IP. But as per you WS-X6748-GE-TX is a dual-channel line card which can only be installed on slots 9-13. Figure 1-9 Catalyst 6513 Switch Internal Airflow . Do I need to replace the IOS on the new supervisor blade to make sure it is the same as the IOS image that is on the Active supervisor module, or will. is this the case. 37 You Save: $1,552. SG350-52MP. Log In. Status: End of Sale | End-of-Support Date: 31-Oct-2025. Syslog severity is 7 (debugging), but before t. In any case, the numbers would not be all zero if any flow control were occuring. Cisco announces the end-of-sale and end-of-life dates for the Cisco Meeting Server 1000 M5v2. WS-C6K-13SLOT-FAN fan tray. show memory debug leaks summary Command Example . Replacement Product Description Additional Information WS-C6513 Catalyst 6500 13-slot chassis, 20RU, no PS, no Fan Tray. Contact Us for Cisco Software Downloads and TAC Support; Basket ; Contact Us +44 333 800 4357 +1 813-421-2951 . The ports on the exisiting module don't use all the same setti. 0E and IOS 15. Hi Baris, You need to create two sequence. 2(1)SY7. 652). Configuring CISCO routers 1800, 2600, 2800, 4500 series and other Network monitoring tool like CA spectrum. 00. Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 6816 10 GE Line Card and Select Accessories. Supported on Cisco Catalyst 6503-E, 6504-E, 6506-E, 6509-E, 6509-V-E, 6513-E. The noc will host some servers like nms, aaa, call manager, video streaming and antivirus stuff. 2 User group:• Chassis sizes range from 3-slot (Cisco Catalyst 6503 Switch) to 13-slot (Cisco Catalyst 6513 Switch) High-Speed WAN Interfaces • Provides high-speed WAN, ATM, and SONET interfaces that are compatible with other core-network routers. . Cisco Catalyst and Meraki switches bring wired and wireless together to drive digital transformation. This document explains the step-by-step procedure to upgrade the software image on Catalyst 6000/6500 series switches that run Catalyst Operating System (CatOS) on Supervisor, Cisco IOS® on MSM/MSFC and Cisco IOS System Software. I have a 6513 with two 4K watt supplies and two 720 sups (12. Hello, We have 2x 6513 non E working in VSS mode. 10-30-2022 03:00 PM. x. the 6513-VS-SUP2T-10G supervisor engines do support VSS. This appears to me as incomplete information since the C881-K9 is without the AdvIPservices license. 5678. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. 1. 2(2)T1. Cisco Catalyst 6513 Switch (Non-E chassis only). I received an alert this aft stating that the far 6513 was unreachable and the port channel int PO3 had gone down, the 2 10 gig interfaces had also gone down on either. bin" · Problem Statement: System diagnostic reports on module number 12 show that the online tests for the system variable number “ 36, TestErrorCounterMonitor ” has failed the diagnostics tests five times. 10/100/1000, 1G, 10G, 40G ports. Bias-Free Language. 0E and IOS 15. x 26-Aug-2016. 2. . Once you move to the new hardware, you can change back. 3-2-17. You'll need to arrange a downtime to reseat the line card. EOSL Info Center. We noticed they are end of support next summer. ? I need a replacement that has. 12. The forwarding engine on Supervisor Engine 2T is capable of delivering high-performance forwarding for Layer 2 and Layer 3 services. The last day to order the affected product(s) is October 30, 2020. 99 USD. Note: WS-X6500-SFM2 and WS-C6500-SFM in combination with the Supervisor Engine 2 deliver an increase in available system bandwidth from the existing 32 Gbps to 256 Gbps. Table 1 describes the end-of-life milestones. Hi, We are trying to upgrade our 6807 VSS switches to 15. The second module was missing the file it need to boot. 0. Customers may be able to continue to purchase the Cisco Catalyst 6513 Switch (Non-E chassis only) through the Cisco Certified Refurbished Equipment program. 07-21-2011 04:26 PM. End-of-Sale and End-of-Life Announcement for. The last day to order the affected product(s) is October 30, 2020. Background Information. Cisco Catalyst 6500 Series Services SPA Carrier-600 16/Sep/2008. Essentially each floor is its own vlan. tar is a k9 (crypto) image. $87. Labels: Labels:Options. Cisco announces the end-of-sale and end-of life dates for the Cisco Catalyst 6513 Switch (Non-E chassis only). EN US. 4. Catalyst 6513 chassis . please guide me about load balancingCisco IOS® Software— no power enable module slot. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories. The last day to order the affected product(s) is October 31, 2017. Installation Accessory Kit. Unless specified, documentation for the Cisco Catalyst 6800 Series Switches is applicable to all models. The last day to order the affected product(s) is November 1, 2006. When both inputs are active but at least one is operating at low line (110 VAC nominal voltage), or a single input is active and running. This section provides a procedure for installing either a Catalyst 6513 or Catalyst 6513-E switch chassis in a rack assembly and installing the optional cable guide assemblies. 536. Cisco Catalyst 6500 Series 10/100- & 10/100/1000-MBPS Ethernet Interface Modules Data Sheet 14/Jan/2016. Cisco's End-of-Life Policy. 您可以查看最适合您的特定需要的可用 Cisco Catalyst 6500 系列交换机 产品列表。. system power redundancy mode = combined. All rights reserved. The last day to order the affected product(s) is October 30, 2020. The 13-slot Cisco Catalyst 6513-E Switch chassis is ideal for high-performance, high-port-density Fast Ethernet, Gigabit Ethernet, and 10 Gigabit Ethernet aggregation throughout the network, including: 13 slots, 19 RU. it looks like this caused issues with other connections through the 6513. The Catalyst 6500 can aggregate up to eight physical Fast Ethernet, Gigabit Ethernet or 10Gigabit Ethernet links into a single virtual link using Cisco’s Port Aggregation Protocol (PAgP) or IEEE 802. Cisco's End-of-Life Policy. Buy Cisco Network Accessory WS-C6513-RACK. Cisco TAC will immediately replace your blade (if, of course, you have a valid service contract). Find quality network accessory products at discounted prices. com 18799: May 8 14:34:39. The Catalyst 6513 switch or Cisco 7613 router chassis has 13 horizontal slots. acf0) MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec, reliability 255/255, txload 19/255, rxload 9/255 Encapsulation ARPA,. The Future Is 40 Gigabit Ethernet White Paper (PDF - 2 MB) Virtual Private LAN Service on Cisco Catalyst 6500 Supervisor Engine 2T. We want to replace EOL WS-X6548-RJ-45 modules on Cisco 6513 ( non E-chassis) which are currently on slot-1,2,3 and 4 and when we look at cisco site the suggested replacement module is WS-X6748-GE-TX. Cisco Catalyst OS 7. Enclosu. *2 Search for EOL8162 at cisco. Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. The WS-C6513-E Cisco Catalyst 6513 Enhanced Chassis is a high-end switch designed for use in enterprise-class data center and service provider environments. Beginner Options. Replacement Product Description Additional Information WS-C6513 Catalyst 6500 13-slot chassis, 20RU, no PS, no. Cisco EnergyWise IOS Configuration Guide for Catalyst 4500 Switches, EnergyWise Version 2. 3, address is 1234. Removal and Replacement Procedures; Power Supply Specifications; Transceivers, Module Connectors, and Cables Specifications. bin from disk0: The box has the following memory: 458720K/65536K bytes of memory - DRAM I believe. The Cisco Catalyst 4500 Series is a mid-range modular chassis network switch. Les clients ont jusqu'au 30 octobre 2020 pour commander les produits concernés. A, B and C. and what command need to enabled on switch 6513-2. 146. A system configured for VSS will be capable of delivering up to 8 Tbps of system bandwidth. Options. com. The Cisco Catalyst 6513-E with Cisco Catalyst 6500 Series Supervisor Engine 720 will have the same bandwidth caveats that exist on the current non-E 6513 chassis. EN US. The WS-X6748-GE-TX Cisco Catalyst 6500 48 Ports Switch Module is a powerful and innovative device that provides additional connectivity options and features to Cisco Catalyst 6500 Series switches. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. redundant routing and forwarding engines. Right now the lab setup is firewall > 6513 > lab computer. The Series includes the E-Series chassis and the Classic chassis which is manufactured in four sizes: ten-, seven-, six-, and three-slot. n. View as List Grid. 2 (1)E 10-May-2015. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories. The Cisco 10GBASE-LRM Module also supports link lengths of 300m on standard Single-Mode Fiber (SMF, G. You can add, replace, or remove modules without interrupting the system. The WS-C6513-E also features hot swap module replacement as well as modular design and is compliant with FCC Part 15 A, NEBS level 3, EN50082-1, CSA 22. Buy Cisco Network Switch WS-C6513-IM. Catalyst 6503-E Switch: Access product specifications, documents, downloads, Visio stencils, product images, and community content. sh diag result modul 1 detail . Cisco's End-of-Life Policy. Table. Warranty. Best way to get lowest price of Cisco Catalyst 6513-E Switch which provides high port densities that are ideal for many wiring closet, distribution, and core network as well as data center deployments with exceptional functionality and flexibility. In these chassis, the slots can be used as follows:. Can any one tell me, what i have to d. Don't want to be burned by that one. In our Data Center (Ph-V. . Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center. This document is Cisco Public Information. Cisco Catalyst 6500, 6800 Series with Sup2T: 2 Tbps per chassis. . The Cisco ® Catalyst ® 6500 Enhanced Series Chassis will be capable of delivering up to 180 Gbps of per-slot bandwidth with a system capacity of up to 4 terabits per second. Cisco Catalyst 6500系列Supervisor Engine 1A、交换矩阵模块1 Catalyst 6503、6506和6509 Supervisor Enigne 1A-2GE配线间捆绑 以及Catalyst 6509 16端口和32端口千兆以太网捆绑终止销售 (EOS)和产品生命期终止 (EOL)声明 26-Aug-2016. co. com. I wish to disable Telnet and configure ssh on Cisco 6513 switch with the following ios version: Cisco IOS Software, s72033_rp Software (s72033_rp-IPSERVICES_WAN-M), Version 12. 2(18)SXF4. The C6513-E also features hot swap module replacement, modular design, NEBS level 3, AS/NZ 3548 Class A, EN50082-1, VCCI Class A ITE, EN55022. (total 4x WS-CAC-3000W) Can we change WS-CAC-3000W to WS-CAC-6000W without downtime ? Can WS-CAC-3000W will work together with WS-CAC-6000W ? Thank you in advance. The last day to order the affected product (s) is October 30, 2020. 157. On a Cisco Catalyst 6503-E and 6504-E module current is @50V; On. Currently we have 3 sites. Additional Information . Learn more. Cisco Systems ® announces the end-of-sale and end-of life dates for the Cisco Catalyst 6500 Series Supervisor Engine 2 Related Memory Modules. The Catalyst 6513-E switch chassis is designed to install in standard 19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and ETS 300-119 standards. Communities. x 26-Aug-2016. The documentation set for this product strives to use bias-free language. Cisco 550X Series Stackable Managed Switches Overview. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Report Inappropriate Content 03-10-2009 02:27 AM - edited 03-06-2019 04:29 AM. Replacement Product Description . Catalyst 4500 Series Switch Software Configuration Guide, Release IOE XE 3. Search for EOL8168 at cisco. Cisco EnergyWise IOS Configuration Guide for Catalyst 4500 Switches, EnergyWise. Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles and accessories. Components Used. We reboot after changing the boot command and it seems as the upgrading process go through,. Status. Product: CON-OSE-C6513VPN Product Description: SNTC-8X5X4OS Cisco 6513 IPSec VPN : Service Category: N/A : Global Price in USD: $42988. I am capturing traffic with Netdr (), but the output has a few information. Catalyst 6513, Cisco 7613 . Especially if the rack and 6513 is in-place and retrofitting the cable management and/or whole caninet is just not feasible, economicaly or resource-wise. 2 (18)SXF16) a customer just brought used. Features and benefits include the following: PoE scalability: Support for up to 420 IEEE class 3 (15. I a. My question is, is this even possible? How can i set up the supervisors to when one fails the other takes over? any help is greatly appreciated. WS-C6513-FWM-K9-RF End of Support Date (EOS): Search our stock for refurbished used Cisco. Alta Tech stands behind our products, offering tech support, as well as replacement products when needed, or a refund for return. WS-X6148-45AF. Supervisor Engine 2T. 1 results for Cisco Catalyst 6513-E Switch. Cisco Catalyst 6807-XL Switch - End-of-Support Date: 30-Apr-2027. For an. Options. Cisco Catalyst 6500 Series 10/100- & 10/100/1000-MBPS Ethernet Interface Modules Data Sheet 14/Jan/2016. Problem Description: Power supply [dec] output has dropped A drop in output power was detected in the specified power supply. It consists of 4 port groups of 4 ports each. This document explains the step-by-step procedures to upgrade the software images on Catalyst 6000/6500 Series Switches with redundant Supervisor Engines that run in Hybrid mode (Cisco Catalyst Operating System (CatOS) on Supervisor Engine, and Cisco IOS on Multilayer Switch Feature Card (MSFC)) or Native mode (Cisco IOS System. Cisco Catalyst 6500 Series Mixed Media Gigabit Ethernet Modules 06/Aug/2014. End-of-Sale Date: 2006-11-01 . Table 1. When you. I haven't removed the old module as 36 ports are still in use. Data Sheet © 2010 Cisco and/or its affiliates. This document is a guide to cables and connectors for Catalyst 6500/6000, 5500/5000, and 4500/4000 series switching modules and Catalyst 2900/3500 XL, 2940, 2970, 2950/2955, 3550, and 3750 series fixed-configuration switches. the line card doesn't seem to be available on Configurator. Buy or Renew. Cisco WS-C6513-E Cisco Catalyst 6513 Enhanced Chassis with Fan Module. Cisco Catalyst 6500 Series10/100 and 10/100/1000 modules are the key enablers of a Borderless Network access solution. Not running iSCSI; however, this is what some of my ports look like with flow control working on a 48 port card in a 6513. 11-16-2016 05:59 AM - edited 03-08-2019 08:11 AM. Replacement Product Part Number . Up to 8092 bytes per frame. The Gigabit Ethernet modules serve campus and data center networking requirements in enterprise, commercial, and service provider environments. 6 Cisco Voice Daughter Card WS-F6K-VPWR-GE SAD080203DG 1. Contact. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3C, Select 67xx Line Cards, and Accessories 06/Jan/2015. Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles and accessories. Hello Jim, sh inventory. Cisco Catalyst 6513 IPSec VPN SPA Security System with Supervisor Engine 720-3B, IPSec VPN SPA, Services SPA Carrier Card, fan tray modules and IOS release 12. The last day to order the affected product(s) is October 31, 2021. 78. The module is marked as power-down in the Status field of the show module command output. 17. Manufacturer Cisco Systems, Inc; Manufacturer Part Number WS-C6513-E; Brand Name Cisco; Product. Solved: Hello Gents, Please let me know if we can configure VPC Between N5010 and 6513(coreswitch). Regular price $149. Chinese; EN US; French; Japanese; Korean; Portuguese; Log InI have a cisco 6513 configured to use wccp v2 with a RedHat AS5 server running Squid 2. Empty chassis weight: 102 lb (46. The SFPs that used are XENPAK-10GB-LR forDisconnect all Ethernet cables from the switch. The chassis is NEBS L3 compliant. The last day to order the affected product(s) is April 30, 2017. Chinese; EN US; French; Japanese; Korean; PortugueseHi all will these be compatble do i need to consider any info. Pull the old one completely out, put the new one completely in. Storage; Server; IBM Server Maintenance; HPE Server Maintenance; DELL Server Maintenance;Looking for a bit of design help We currently run 1 Cisco 6509 (CatOS) for our production network. 6513 There is currently no replacement product available for this product. [email protected] (31)SGA 15-Oct-2013. Step 2 Position and install the two lower brackets in the rack using 8 10-32 or 12-24 screws (4 on each side). Router has many WAN links with MPLS and p2p connectivity. What is the risk? What would you expect? I have installed the same OS and IOS ver as the existing. They include a 48-port Gigabit Ethernet Copper Module and 48-port Gigabit Ethernet Fiber Module. This document provides a sample configuration of IEEE 802. The document describes a procedure to use while the Supervisor Engine module is still up and running in the chassis, and a procedure to use when the Supervisor Engine module is removed from the chassis. - -. BTW, enabling non-Cisco transceivers doesn't guarantee they will work. 0223 Search: SearchThe Cisco Catalyst 6500 Series Switches provide superior Power over Ethernet (PoE) scalability. platform that maximizes network uptime with stateful failover capability between. In order to verify if adequate power is available in the system in order to turn the power on for a module that was previously powered down, issue one of these commands: CatOS— set module. The last day to order the Cisco Catalyst 6500 Series Supervisor Engine 2 Related Memory Modules is. Step 1 Remove the two screws that secure the VTT module. BOOT variable = sup-bootdisk:s3223-ipbase_wan-mz. ) Replacement Products of Cisco ISR 1900 Series: End-of-Sale Product Part Number. Switches Mapping Cisco VS. Book Contents Book Contents. Limited warranty - advance parts replacement - 90 days - response time: 10 days . Hi, We are trying to upgrade our 6807 VSS switches to 15. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. The last day to order the affected product(s) is June 30, 2020 . when i have this IOS s72033-ipservicesk9_wan-mz. Beginner Options. Switch Replacement Procedure. Another important issue, is the cooling for the 6500 switches, since these Cisco switches have a special case, the fresh air enter the chassis from the right and the bad air exit the chassis from the left. You are running a hybrid OS on 6513 i. i want to take cisco 6513 into network and i want do do load sharing configuration between tease two switches. The MTS 6513 has a LCD display which can be used to : run applications in stand alone mode without a PC. Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 4948 Switch. EOL5756, Amended. *1Search for EOL6869 at cisco. Hi, we got a phenomenon here. Q & a. Outlet. 60950, CISPR 22 Class A, EN 60950, EN 61000-6-1, UL 1950, VCCI Class A ITE, AS/NZS 60950-1, AS/NZ 3548 Class A, EN55024, EN55022 Class A and EN50082-1. 122-35. e for Active/Standby). No. In the event of failover, the users will still be able to to get to the primary (re: non-standby) address. I found the problem, the "ip dhcp smart-relay" is a valid command for 6513 and above IOS. If i have load on network like when there is Video conference session then i m getting too much delay from our LAN. 8 26-Feb-2015. The bulletin states that the replacement model is the C881-K9. SXH3. We have to make the Policom / Microsoft phones work on the network. 06-15-2009 08:41 AM. Available Order. acf0 (bia 1234. {Switch Replacement for J9772A} $1,495. com). I am having problems. Cisco’s 550X Series switches are built to safeguard your technology investment as your company expands. EOS & EOL: Select Cisco Catalyst 6500 Series Components-Updated 03/Aug/2005. Buy Cisco Network Accessory WS-C6513-CSM. Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type. Le centre d’assistance technique de Cisco (TAC). WS-C6513-FWM-K9-RF. In my case server 1 is connected on switch 6513-1 and server 2 is connected on switch 6513-2. com. I wanted to gather a consensus of the recommended best-practice steps for upgrading (2) 6513s core chassis units running IOS with dual-720s in each. 1Q (dot1q) trunking between a Cisco Catalyst 3550/3560/3750 switch that runs Cisco IOS ® Software and a Catalyst 6500/6000 series switch or Catalyst 4500/4000 series switch that runs Cisco IOS Software. End-of-Sale and End-of-Life Announcement for the Cisco Nexus 7010 and Cisco ASA 5585-X Chassis (with SSP-60) Bundle 02/Dec/2014. 4644. vlan access-map SECVLAN_MAP 10. ACL's on the MSFC should be applied to all inter-VLAN packets that flow through the 6513 regardless of any type of "bypass the MSFC" routing that is being done. WS-C6513-2500AC= Catalyst 6513 Chassis w/ 2500W AC Power Supply . or you can RMA it and get a replacement. Hello, We have 2x 6513 non E working in VSS mode. The Senior Engineer gave me a project and thought this would be a good place to start to get some help. In addtion to Ankur's post if session 15 or 16 command doesnot work then you can use " Switch Console " command. The last day to order the affected product(s) is October 30, 2017. CHAPTER 1-1 Cisco IOS Software Configuration Guide, Release 15. All the servers, desktops and trunks connected to this line card are showing high response time (>500ms) locally. Kind Regards, Wilson SamuelCisco Catalyst 6506-E, Catalyst 6509-E and Catalyst 6513-E Switches with Supervisor Cards (VS-S2T-10G and VS-S2T-10G-XL) and Line Cards (WS-X6908-10G and WS-X6908-10G-2TXL) FIPS 140-2 Level 2 Non-Proprietary Security Policy Overall Level 2 (Sections 3 and 10 Level 3) Validation Version 1. . Save the config; and. Below are the log for your reference. Note This action assures that the EMI gaskets on all of the modules are fully compressed in order to maximize the opening space for the new or replacement supervisor engine. Documented cables, ports, jacks, and description fields in IOS. We are planning to replace the second sup live on a very busy 6513. 06-11-2007 11:19 AM. I have uploaded 1. If the VMWare NIC supports LACP, then you can use mode 'active'. WS-C6513-E - Cisco 13-Slot Chassis for Catalyst Enhanced C6513. . Check if the commands needed are available. Both switches need to run the same IOS version (check with 'sh ver'). Enclosure type: 20RU Desktop Power Details: 3000W AC, 4000W AC, 6000W AC, 8700W AC, 2500W DC, 4000W DC,. Cisco Catalyst 6500 Series Port Density Information, WAN Modules and Interfaces Maximum System Port. IT Hardware Maintenance. This test is important to pass and usually indicates a transient or permanent hardware issue on failure. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. 8 26-Feb-2015. Cisco 6513 Span session Limit fhoban. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. I was wondering what logic, if any, others use to place the modules in a chassis. Go HERE . Both switches need to run the same IOS version (check with 'sh ver'). The 100BASE-X, 100BASE-FX, and 10BASE-FL modules provide another alternative for the access and distribution layer and. Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 6500 Switch Accessories. ROMMON Release Notes for the WS-X45-SUP7-E, WS-X45-SUP7L-E, and WS-C4500X Family of Switches 14-Mar-2019. Figure A-15 4000 W DC-Input Power Supply . Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. The 6513 has been sitting in the office for a while and my boss would like to have it up and running so we can test blades; as in running traffic through the ports etc. We a. int vlan (mgmt_vlan) ip. 05-21-2012 12:49 AM - edited 03-07-2019 06:48 AM. Mar 6 09:55:04. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. We have several end user Catalyst 6513 switches (non E series) that are maxed out with 6X48 series blades. 82 $2,743. 0E 31-May-2019. 3 December 2012I have a Cisco 6513 Core Switch, which is in a vtp domain and the core is the Server. . Managing and monitoring network devices Nexus-7K C7010, Catalyst 6513, Cisco ACE-4710, Catalyst- 2950,2960G,3560G, 3750 and maintain log report .